Whether you have an existing furnace in your home or your new construction project includes a forced air heating system, the LDJ A-Maize-Ing Heat furnace can meet your needs. Available in both a 100,000 BTU and a variable rate 165,000 BTU model, the LDJ furnace can be connected to the central ductwork system in your home. The furnace is made as a stand alone system, and will operate with your air conditioning unit during the cooling season.

A-MAIZE-ING HEAT® CORN FURNACE/STOVE AND BOILER MANUFACTURED BY LDJ MFG INC INTRODUCING A TRULY EFFICIENT FURNACE AND BOILER In these times of high energy costs, it makes sense to use a heat source that utilizes a resource that is readily available and cost effective. The A-Maize-Ing Heat® furnace and boiler burn shelled corn, a renewable local commodity. Corn costs less per BTU than other heat sources, plus benefits the local economy by generating business for farmers. The low cost of shelled corn, together with the efficient burning process of this furnace or boiler, produces an ecologically safe home heating system.
  • BURNS CLEAN - NO MORE CREOSOTE
  • The A-Maize-Ing Heat® furnace and boiler feed the corn into the bottom of the combustion chamber, therefore providing the most efficient fuel consumption. The residual ashes are then spilled over the top of the combustion ring into the ash pan. This process, in effect, self cleans the combustion chamber.
  • THE FIRST UL LISTED
  • The A-Maize-Ing Heat® furnace and boiler are the first shelled corn fired central furnace and residential boiler to be listed by Underwriters Laboratories. Using a dual auger drive system to meter the fuel allows for the precise and safe control of combustion. The UL listing assures you of a safe and quality product.
  • SAFE, COMFORTABLE HEAT
  • Your home's thermostat electronically controls the fuel feed system and blower to provide a constant temperature. The furnace or boiler will remain lit as long as the bin contains corn, and will shut down automatically if the fuel supply is depleted. The low stack temperature and absence of creosote buildup eliminates the possibility of chimney fires.
  • A BETTER ALTERNATIVE
  • The A-Maize-Ing Heat® corn burning furnace and boiler have many advantages over wood heat. There is no daily maintenance. With 100,000 BTU or 165,000 BTU output you could easily heat an entire house. The large storage bin holds up to 10 days supply of fuel, which is automatically fed, into the combustion chamber as needed. There's no need to load the furnace several times a day. The use of corn also eliminates the bark mess, insects, splinters, and storage & handling problems connected with wood fuel. No chainsaws, wood splitters, or trailers to buy and maintain.
  • BURN OTHER BIOMASS FUEL
  • An LDJ A-Maize-Ing Heat® system can also burn other biomass fuels including wood pellets, wheat, grain, sorghum, soybeans, fruit pits, pelletized waste or other pelletized combustable materials that can be fed through the 2" augers.
  • QUALITY CONSTRUCTION
  • The A-Maize-Ing Heat® furnace and boiler feature quality construction for long-lasting performance. 14-gauge steel is used on the heat exchanger, and a large heavy cast iron fire pot ensures long life. A one year warranty is included on electrical parts, and a five year limited warranty on the burner and heat exchanger. LDJ Mfg Inc of Pella, Iowa builds their products with pride.
  • LDJ Mfg. Exclusive Product Improvements.
  • 165,000 BTU VARIABLE RATE*
  • This feature enables your corn furnace to produce from 80,000 BTU to 165,000 BTU by simple setting changes. Set for 80,000 BTU in the early fall and then easily go to 165,000 BTU in the heart of the winter season.
  • CORN HOPPER SHUTOFF*
  • This feature enables you to open or close the fuel flow into the auger system from the hopper.
  • COPPER FEEDING TUBE*
  • The feeding tube from the hopper to the corn furnace has be changed from plastic to copper. This eliminates the possibility of plugging the tube and makes the unit quieter when running.
  • SLOPED LIP INSIDE DOOR
  • The bottom lip of the entrance door to the burn pot is now sloped. This eliminated ashes from building up on the ledge and falling out when you open the door. The furnace is safer and cleaner because of this change.
  • COUPLER SYSTEM FOR RIGHT/LEFT FEEDING
  • The furnace has a interchangeable coupler system on each side of the unit. This allows for flexibility of installation in the field for right or left hand feed applications. The removal of the couplers also narrows the unit to 27 inches for smaller doorways during installation.
  • IMPROVED FINISH ON UNITS
  • The painting process has been changed to ensure a long-lasting and durable finish.
  • IMPROVED HEAT EXCHANGER
  • The heat exchanger has been reinforced with heavier supports and steel.
  • *Upgrade kits can be purchased to upgrade existing units with these exclusive improvements.
  • A-maiz-ing Heat CORN FURNACE SPECIFICATIONS
  • Model LDJ620-9 & LDJ620-10
  • Thermostat controlled
  • BTU's
  • 100,000 or 165,000
  • Dimensions-Furnace
  • 53"H x 27"W x 46"D
  • Dimensions - Bin
  • 48"H x 36"W x 51"D
  • Weight - Furnace.
  • 440 lbs
  • Weight - Bin
  • 50 lbs.
  • Flue Pipe
  • 6"
  • Plenum Openings
  • 14"sq.
  • Heat Exchanger
  • 14 gauge steel
  • Fire Pot
  • Cast Iron
  • Air Filter
  • 20" x 20" x 1"
  • Bin Capacity
  • 14 bushels
  • Hot Air Blower
  • 1/2 HP - 3 speed
  • Clearance to Combustibles
  • Top 32" Front 30" Side 6" Rear 18"
  • LDJ Mfg. Exclusive Product Improvements.
  • 165,000 BTU VARIABLE RATE*
  • This feature enables your corn boiler to produce from 80,000 BTU to 165,000 BTU by simple setting changes. Set for 80,000 BTU in the early fall and then easily go to 165,000 BTU in the heart of the winter season.
  • CORN HOPPER SHUTOFF*
  • This feature enables you to open or close the fuel flow into the auger system from the hopper.
  • COPPER FEEDING TUBE*
  • The feeding tube from the hopper to the corn boiler has be changed from plastic to copper. This eliminates the possibility of plugging the tube and makes the unit quieter when running.
  • IMPROVED FINISH ON UNITS
  • The painting process has been changed to ensure a long-lasting and durable finish.
  • *Upgrade kits can be purchased to upgrade existing corn boiler units with these exclusive improvements.
  • BOILER SPECIFICATIONS
  • Model LDJ991-9 & LDJ999-10
  • Thermostat controlled
  • BTU's
  • 100,000 or 165,000
  • Dimensions-Boiler
  • 61"H x 22"Diameter
  • Dimensions - Bin
  • 48"H x 36"W x 52"D
  • Weight - Boiler
  • 510 lbs
  • Weight - Bin
  • 50 lbs.
  • Flue Pipe
  • 6"
  • Fire Pot
  • Cast Iron
  • Bin Capacity
  • 14 bushels
  • Tank Capacity
  • 18 Gallons
  • Combustion Blower
  • 60 CFM
  • Clearance to Combustibles
  • 18" From Flue connection